• Join
  • Current Location: Home Technical FAQ
  • Technical Technology
    Products / Products
  • PubDate: 2017 - 11 - 25
    Brand:  GIZOModel number:   LZ-701z auto lidMaterical:   ceramic+ ABS plasticDrain distance:   300/400mmSize:   820*430*760mmFlush:   4/6LDrainage pattern:   s-trapFlushing Method: siphon jetRemote control:   YesPacking:Wood+carton+foamPower: 110V/220VDelivery Time: Within 30 DaysFunction:  rear wash, feminine wash, massage wash, self-cleaning mozzles, heated water for wash, heated seat, warm wind for dryer, auto lid, auto flush, easy installation, night light, FM radio, voice alarm soft closing and so on.
  • PubDate: 2017 - 11 - 25
    Brand:  GIZOModel number:   LZ-702z auto lidColor: whiteMaterical:   ceramicDrain distance:   300/400mmSize:   820*430*580mmFlush:   4/6LDrainage pattern:   s-trapFlushing Method: siphon jetRemote control:   YesFunction:  rear wash, feminine wash, massage wash, self-cleaning mozzles, heated water for wash, heated seat, warm wind for dryer, auto lid, auto flush, easy installation, night light, FM radio, voice alarm soft closing and so on.
  • PubDate: 2017 - 11 - 25
    Brand:  GIZOModel number:   LZ-703zMaterical:   ceramic+ ABS plasticDrain distance:   300/400mmSize:   820*430*760mmFlush:   4/6LDrainage pattern:   s-trapFlushing Method: siphon jetRemote control:   YesPacking:Wood+carton+foamPower: 110V/220VDelivery Time: Within 30 DaysFunction:  rear wash, feminine wash, massage wash, self-cleaning mozzles, heated water for wash, heated seat, warm wind for dryer, auto lid, auto flush, easy installation, night light, FM radio, voice alarm soft closing and so on.
  • PubDate: 2017 - 11 - 25
    Brand:  GIZOModel number:   LZ-701sMaterical:   ceramic+ ABS plasticDrain distance:   300/400mmSize:   750*430*580mmFlush:   4/6LDrainage pattern:   s-trapFlushing Method: siphon jetRemote control:   YesPacking:Wood+carton+foamPower: 110V/220VDelivery Time: Within 30 DaysFunction:  rear wash, feminine wash, massage wash, self-cleaning mozzles, heated water for wash, heated seat, warm wind for dryer, auto lid, auto flush, easy installation, night light, FM radio, voice alarm soft closing and so on.
  • PubDate: 2017 - 11 - 29
    Brand:  GIZOModel number:   JJ-0810Materical:   ceramic+ ABS plasticDrain distance:   300/400mmSize:   760*430*730mmFlush:   4/6LDrainage pattern:   s-trapFlushing Method: siphon jetRemote control:   YesPacking:Wood+carton+foamPower: 110V/220VDelivery Time: Within 30 DaysFunction:  rear wash, feminine wash, massage wash, self-cleaning mozzles, heated water for wash, heated seat, warm wind for dryer, auto flush, easy installation, night light, soft closing and so on.
  • Contact

    Phone:86 757 81260990

    Mail:gizo@gizo.cc

     

    China · GuangDong · FoShan

    Address:Nanhai District, Foshan, China Guangdong small village industrial park, TOYOTA

    About Us FAQ

    (1)Symptoms: none

             Check the part (outlet, plug leakage, power button, the installation of the first contact, the transformer pole, the panel, the computer board)
            Remedy: the power outlet is power? If so, see the missing plug reset button whether the indicator light is displayed or not? Machine power is pressed? Is the cover in good contact with the mounting bar? Is there a secondary output transformer 7V? Is the panel shorted to water? If the above are normal computer board bad.


    (2) Symptoms: water is not hot (other normal)
             Check part (remote control, water tank heater, water temperature sensor, thermal fuse, computer board)
             Remedy: Remote control temperature setting is normal temperature? Seat waiting for 10 minutes, if there is no heat, unplug the measuring tank heating wire at both ends of the resistance is about 92 ohms, and then test the heating tube at both ends of the 92 ohm resistor, if there is no fuse is broken, measuring temperature sensor two End of the resistance (25K ~ 80K) is normal, if the normal computer board is bad, such as changing the water tank, after the test is normal, such as water has been heated computer board bad to be changed together.


    (3) Symptoms: seat temperature is not heating (other normal)
             Check the part (remote control, seat heating wire, temperature sensor, computer board, connectors)
              Remedy: set the heating state with the remote control (seat waiting for 10 minutes) If there is no heating, unplug the seat heating wire measuring resistance at both ends of the 960 +/- 50 ohm, if no wire open, if the measured temperature Sensor resistance at both ends (5K ~ 15K) is normal, the connector is in good contact? If normal, the computer board is bad. Such as change seat ring, change after the test is normal, such as the seat has been heated computer board bad to change together.

    4) Symptoms: the temperature is not hot (other normal)
              Check part: (drying device, computer board)
             Remedy: Measure whether there are 89 +/- 4 ohm resistors at both ends of the drying heating wire frame. If there is no drying device is bad, if yes, confirm the correct. Press the drying key to measure whether there are 220V voltage at both ends of the heating wire frame socket No voltage is bad computer board. As for the drying device should be carefully tested computer board. Note: If the short circuit between the motor sometimes back to increase the load due to speed and slow down the heating wire ledge open, can also cause the computer board D882 scorch phenomenon, then please talk about the computer board and the drying device replaced at the same time.


    5)Symptoms: no deodorant (other normal)
        Check part: (deodorizing fan, computer board)
       Remedy: After confirming the correct seating with a multimeter DC 20V file deodorant fan socket should have 12V voltage if the fan is bad, if there is no bad computer board.


    6) Symptoms: When no one is seated, press the buttocks, women-only, drying can work, and the nozzle cleaning and lighting does not work.

        Check part: (seat, computer board)
         Remedy: Dry with a soft cloth wipe the right seat away from the front 20CM, if not normal, then the seat ring seat sensor often turn, change seat ring, such as type Ⅱ should check the six-wire mouth is in good contact .


    7) Symptoms: seating, press the buttocks, women-only, drying does not work, while the nozzle cleaning and lighting work properly.
         Check part: (seat ring, computer board, patch cord)
         Remedy: Do not use a soft cloth to place the seat sensor directly above the multimeter with a multimeter 20V file sensor line, if 5V is bad sensor (change seat ring) or poor connector, such as 0V computer board is bad.

    8) Symptoms: flashing light flashing (more than 90S)
         Check part: (tank dry reed pipe, solenoid valve, the cover and the mounting bar contact, transformers, computer boards, ceramic water pipes)
         Remedy: Look at the presence of water overflow from the spout, if the test reed switch is connected, such as water overflow, then see the customer home water pressure is greater than 0.4mpa, such as greater than with a multimeter to measure the solenoid valve at both ends of No DC 12V voltage? If there is no transformer sub-secondary AC output, if normal, then the computer board is bad, if the pull-off amount of the valve at both ends of the resistance should be about 30 ohms, if not, the whole bad contact with the mounting bar, such as Yes, the solenoid valve suffocated or clogged filter, such as hearing the water flow may be ceramic water pipes rupture.


    9)Symptom: High temperature alarm (buzzer continuous called dimmer does not flash).
        Check part: (magnetic temperature switch, temperature sensor, computer board)
        Remedy: Unscrew the drainage bolts feel the water temperature by hand is more than 45 ℃ can determine the temperature-sensitive switch is good or bad, after re-water, turn off the water temperature with the remote control heating, the water tank heating plug if there is 220V voltage, if any Computer board is bad, if no water temperature sensor resistance is normal, if not normal, change the water temperature sensor (sometimes on the computer board 3062 sometimes lead sometimes does not conduct, leading to ultra-high water temperature, then change the computer board).

    10)Symptom: Stepper motor alarm (every 3 seconds called 5 sound, cut off the power)
         Check part: (panel, washer, transformer)
         Remedy: First unplug the panel to see if it is normal, such as the normal panel short circuit, such as the phenomenon still check the washer, unplug the optocoupler if normal, the washer is bad, if not normal then detect the transformer secondary output voltage is Normal, if not normal transformer is bad.


    Tell me your requirements and submit your content and we will contact you first!

    Address: small industrial park of TOYOTA village,Nanhai District, Guangdong, Foshan, China  Phone: 86 0757 86432533  
    Copyright ©2005 - 2017 Foshan Jiezuo intelligent Sanitary Ware Co. Ltd.
    犀牛云提供企业云服务